Inquiry
Form loading...
Products Categories
Featured Products

Universal Travel Adapter 100-220V to 15W 5V Voltage Converter Power Adapter Cord Model: ADA150K050S001A

Features
● Wide input voltage: The input working voltage range is 100-240VAC.
● Low power consumption: No-load <0.075W.
● High energy efficiency: Six levels of energy consumption, power efficiency up to 82%.
● Flame retardant insulation: UL94V-0 flame retardant heat resistant material.
● Protection types: Short circuit protection, over current protection, over voltage protection, and self-recovery.
● Convenient conversion: Adapt to five conversion plugs of British, Australian, European, American, and Chinese.
    Poduct Detail Specifications Input Parameter Voltage Range 100~240 VAC Frequency Range 50~60Hz Input Current (Max.) 0.14A @ 230VAC Efficiency (Typ.) 82% Standby Consumption 0.075W Impulse Current (Typ.) 30A @ 100VAC,50A @ 240VAC Leakage Current (Typ.) 0.6mA @ 264VAC, 60Hz Output Parameter Output Voltage 5VDC Voltage Tolerance ±5% Output Current 3000mA Rated Power (Max.) 15W Line Regulation ±3% at full load Max. Capacitive Load 6000uF Load Regulation ±3% Ripple & Noise 50mV (Max.) @20MHz,230V Frequency (Typ.) 65kHz Hold Up Time (Typ.) 50mS @ 100VAC80mS @ 240VAC Environment Operating Temperature -40 ~ +70℃ Storage Temperature -40 ~ +85℃ Storage Humidity 95%RH (Max.) Power Derating 3.6%/℃ @ -40 ~ -25℃2.4%/℃ @ +50 ~ +70℃,5VDC2.7%/℃ @ +55 ~ +70℃ Temperature Coefficient ±0.02%/℃ Soldering Temperature 260±5℃ @ Wave Soldering, 5~10s360±10℃ @ Manual Soldering, 3-5s Protection Function Short Circuit Long term short circuit, auto recovery. Over Current ≥120%IO auto recovery Over Voltage ≤7.5VDC @ 5V output Reliability MTBF ≥300000H @ 25℃ Safety Standards / Directives Medical Safety EN60601-1 CE Compliant Isolation Voltage (Min.) Input to Output 4000VAC @ 1 minute test and the leakage current is smaller than 5mA. EMC EMI Parameter Standard Test Level / Note Conducted emission EN55011(CISPR11) /EN55032(CISPR32) CLASS B Radiated emission EN55011(CISPR11) / EN55032(CISPR32) CLASS B Voltage flicker EN61000-3-2 - Harmonic current EN61000-3-2 - EMS Parameter Standard Test Level / Note Electrostatic discharge IEC/EN61000-4-2 ±8KV/Contact±15KV/Air Radiate susceptibility IEC/EN61000-4-3 10V/m Electrical fast transient burst IEC/EN61000-4-4 ±2 KV Surge IEC/EN61000-4-5 ±0.5 kV, ±1 kVL to N Conducted susceptibility IEC/EN61000-4-6 10V(r.m.s) Voltage dips and interruption IEC/EN61000-4-11 0%UT 0.5cycle at 0°,45°,90°,135°,180°,270°,315° 0%UT 1cycle70%UT 25/30 cycle0%UT 250/300 cycle