AC/DC Wide input voltage Low power consumption Small size Full protections High reliability Medical Power Module ADM360K240S001A

Features: ● Wide input voltage: the input working voltage range is 100-240VAC ● Low power consumption: No-load <0.075W ● High Energy Efficiency: Six levels of energy consumption, power efficiency up to 90% ● High reliability: Comply with EN60601-1 CLASS Ⅱ safety level and 2×MOPP insulation protection level, and pass CE ● Flame retardant insulation:UL94V-0 flame retardant heat resistant material ● Protection types:short circuit protection, over current protection, over voltage protection, and self-recovery ● Small size:65.8*44.5*31.49mm, it can be put into products with high volume requirements
    Specification Input Parameters Voltage Range 100~240 VAC Frequency Range 50~60Hz Input Current (Max.) 0.7A @ 115VAC,0.5A @ 230VAC Efficiency (Typ.) 90% Standby Consumption 0.075W Impulse Current (Typ.) 10A @ 115VAC,23A @ 230VAC Leakage Current (Typ.) 0.1mA @ 264VAC, 60Hz Output Paremeters Output Voltage 24VDC Voltage Tolerance ±5% Output Current 1500mA Rated Power (Max.) 36W Line Regulation ±0.5% at full load Max. Capacitive Load 2000uF Load Regulation ±1% Ripple & Noise 50mV (Typ.), 100mV (Max.)@20MHz Frequency (Typ.) 65kHz Hold up Time (Typ.) 15mS @ 115VAC80mS @ 230VAC Environment Operating Temperature -40 ~ +70℃ Storage Temperature -40 ~ +85℃ Storage Humidity (Max.) 95%RH (Max.) Power Derating 2.7%/℃ @ -40 ~ -25℃2.4%/℃ @ +50 ~ +70℃,12VDC 2.7%/℃ @ +55 ~ +70℃ Temperature Coefficient ±0.02%/℃ Soldering Temperature 260±5℃ @ Wave Soldering, 5~10s360±10℃ @ Manual Soldering, 3-5s Protection Function Short Circuit Long term short circuit, auto recovery. Over Current ≥130%IO auto recovery Over Voltage ≤27VDC @ 12V output, ≤40VDC @ 24V output IEC Safety Class CLASSII Electric Shock Protection 2×MOPP @ primary to secondary Reliability MTBF ≥300000H @ 25℃ Safety Standards / Directives Medical safety EN60601-1 CE Compliant Isolation Voltage (Min.) Input to Output 4000VAC @ 1 minute test and the leakage current is smaller than 5mA. EMC     EMI         Parameter Standard Test Level / Note Conducted emission EN55011(CISPR11)/EN55032(CISPR32) CLASS B Radiated emission EN55011(CISPR11)/EN55032(CISPR32) CLASS B Voltage flicker EN61000-3-2 - Harmonic current EN61000-3-2 - EMS            Parameter Standard Test Level / Note Electrostatic Discharge IEC/EN61000-4-2 ±8KV/Contact±2、4、8、15KV/Air Radiate Susceptibility IEC/EN61000-4-3 10V/m Electrical Fast Transient burst IEC/EN61000-4-4 ±2 KV Surge IEC/EN61000-4-5 ±0.5/±1 KVProfessional/Family medicine Conducted Susceptibility IEC/EN61000-4-6 3Vm/0.15MHz-80MHz 6Vm(Within15m band) 0.15MHz-80MHz 80%AM,1kHz Voltage Dips and Interruption IEC/EN61000-4-11 0%UT 0.5cycle0°,45°,90°,135°,180°,270°,315°。 0%UT 1cycle 70%UT 25/30 cycle 0° 0%UT 250/300 cycle     Mechanical Specification Dimension 65.79*44.54*31.49mm Enclosure Material Black flame retardant and heat resistant plastics(UL94V-0) Cooling mode Natural air cooling Application